MALDI-TOF Mass Spectrometry Database

From MicrobeMS Wiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.


Introduction

Library-based MS approaches for microbial identification require labeled sets of microbial mass spectra. Starting with version 0.82 MicrobeMS can deal with experimental MALDI-TOF or LC-MS¹ mass spectra and the respective MS databases.
The RKI databases of microbial MALDI-TOF mass spectra contain mass spectral entries from highly pathogenic (biosafety level 3, BSL-3) bacteria such as Bacillus anthracis, Yersinia pestis, Burkholderia mallei, Burkholderia pseudomallei and Francisella tularensis as well as a selection of MALDI-TOF mass spectra from their close and more distant relatives. The RKI mass spectral databases can be used as a reference for the diagnostics of BSL-3 bacteria using proprietary and free software packages for MALDI-TOF MS-based microbial identification. The databases are distributed as zip archives and contain the original mass spectra in its native data format (Bruker Daltonics). MALDI-TOF MS Databases will be updated on a regular basis.
The LC-MS¹ database is an in silico database which has been compiled from Uni-Prot Knowledgebase (Uni-Prot/KB Swissprot and TrEMBL) resources, for details see below).

MALDI-TOF MS databases

The different version of the RKI MALDI-TOF MS database can be downloaded from the following locations:

 1. Zenodo database version 3 (20181130):
    Lasch P, Stämmler M & Schneider A, (2018). Version 3 (20181130) of the 
    MALDI-TOF Mass Spectrometry Database for Identification and Classification of Highly
    Pathogenic Microorganisms from the Robert Koch-Institute (RKI). 
    Zenodo. https://doi.org/10.5281/zenodo.1880975
    Version Nov 30, 2018, creative commons CC BY-NC 4.0 license
 2. Zenodo database version 2 (20170523):
    Lasch P, Stämmler M & Schneider , (2017). Version 2 (20170523) of the 
    MALDI-TOF Mass Spectrometry Database for Identification and Classification of Highly
    Pathogenic Microorganisms from the Robert Koch-Institute (RKI). 
    Zenodo. http://doi.org/10.5281/zenodo.582602
    Version May 23, 2017, creative commons CC BY-NC 4.0 license
 3. Zenodo database version 1 (20161027):
    Lasch P, Stämmler M & Schneider A, (2016). A MALDI-TOF Mass Spectrometry
    Database for Identification and Classification of Highly Pathogenic Microorganisms from 
    the Robert Koch-Institute (RKI). Zenodo. http://doi.org/10.5281/zenodo.163517
    Version October 27, 2016, creative commons CC BY-NC 4.0 license

LC-MS¹ databases

The original concept of microbial identification by means of MALDI-TOF MS measurements of cultivated microbial cells and spectral distance-based comparison with entries of a spectral library has been adapted for LC-MS¹ microbial identification, see Preprint Lasch P, Schneider A, Blumenscheit C and Doellinger J, Identification of Microorganisms by Liquid Chromatography-Mass Spectrometry (LC-MS¹) and in silico Peptide Mass Data, bioRxiv (Dec 10, 2018), doi:10.1101/870089.

 1. Lasch P, Schneider A, Blumenscheit C, Doellinger J. (2019). In silico Database for 
    Identification of Microorganisms by Liquid Chromatography-Mass Spectrometry (LC-MS¹). 
    Zenodo. https://doi.org/10.5281/zenodo.3573996
    Version December 13, 2019, creative commons CC BY-NC 4.0 license